Material: Carbon Steel
Flow Direction: Centrifugal
Pressure: Low Pressure
Certification: ISO, CE, CCC, Appointed
Speed: 1450/2900r/M
Power: 4.4-264kw
Customization:

Contact Supplier

Gold Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Product Parameters
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
XH-TNF
Volume
89-1880m³/S
Machine No.
9 Machine Number
Total Pressure
256~9930 PA
Color
Red/Yellow/Customized
Customized
Design and Technical Drawing Can Be Customized
Voltage
420V
Single Motor Current
4.85/2.79~240/139/80.5A
Motor Qty
2
Transport Package
Strong Wooden Case Exporting Standard
Trademark
Kuang Feng
Origin
China
HS Code
8414599099
Production Capacity
1000sets/Month

Product Description

Specially Designed Fan for Tunnel Ventilation and for Smoke Evacuations

Structure and Features

A. The series of fans include air collector, class I main fan, class II main fan, silencer, motors, venti pipe interface and other components. The body and the structure are made of welded steel plate, the impeller adopts wing streamlined blade, the fan adopts the motor and the impeller direct connection way, the transmission is reliable, the whole structure is simple compact, sturdy and durable, safe use and convenient for maintainance.
 
B.Compact structure, low noise, high efficiency, good wind performance, high wind pressure, stable operation in the work area, wide application range and so on. According to the length of the digging surface and the different ventilation requirements of the roadway, you can use the machine, but also graded use, thereby reducing energy consumption, tunnel tunneling is the ideal local ventilation equipment.
 
C. According to the specific requirements of the tunnel project, the company can set the diameter in the fan inlet part, and then with the front fan docking, in order to achieve long-distance tunnel relay air to achieve better ventilation effect.
Specially Designed Fan for Tunnel Ventilation and for Smoke Evacuations


Specially Designed Fan for Tunnel Ventilation and for Smoke Evacuations
Product Parameters
Local Fan Model Motor Power
(KW)
Volume
(m3/s)
Total Pressure
(Pa)
Minimum Casing Fan
(mm)
Blowing Distance
(m)
Weight
(Kg)
Dimension(mm)
D L H
MLF66-1№3 1.5 0.9~1.4 928~575 300 80 51 390 486 230
MLF66-1№3.5 3 1.5~2.4 1263~752 350 150 74 450 562 260
MLF66-1№4 5.5 2.2~3.5 1648~1020 400 200 115 520 649 290
MLF66-1№4.5 11 3.1~5.0 2093~1295 450 300 135 585 728 320
MLF66-2№4 11 2.2~3.5 2923~1811 400 400 130 520 877 290
MLF55-2№4.5 11 3.0~5.2 2276~1275 450 300 140 543 704 375
MLF55-1№5 11 4.2~6.6 1726~1324 450 200 135 600 535 400
MLF56-1№3.15 2.2 1.4~2.1 853~588 300 80 53 374 634 193
MLF56-1№4 4 2.1~3.4 1275~981 400 150 96 477 682 240
MLF68-1№4.5 7.5 2.6~4.2 2256~1177 400 250 145 540 760 270
MLF68-2№4.5 11 2.8~4.3 3237~1471 400 400 195 540 860 270
MLF40-1№5.5 5.5 4.3~5.1 633~475 550 120 720 653 3800 336.5
MLF40-1№6.5 11 7.1~8.4 884~663 650 140 742 772 3800 396
MLF40-1№7 15 8.8~10.5 1025~769 700 140 795 830 4100 425
MLF40-1№7.5 22 10.9~12.9 1177~883 750 150 824 890 4100 455
MLF40-1№8 30 13.2~15.6 1339~1005 800 150 848 950 4350 485
DMLF50-1№5.5 2×5.5 4.8~5.8 1182~515 550 180 948 653 3800 336.5
DMLF50-1№6.5 2×11 7.9~9.5 1651~719 650 200 1120 772 3800 396
DMLF50-1№7 2×15 9.9~11.9 1915~834 700 200 1207 830 4100 425
DMLF50-1№7.5 2×22 12.2~14.6 2198~957 750 220 1293 890 4100 455
DMLF50-1№8 2×30 14.8~17.8 2501~1089 800 220 1340 950 4350 485
 
Ordering instructions
When ordering, please specify the fan number, speed, air volume, wind pressure, outlet angle and direction of rotation, as well as motor model, power, speed and so on.
The most important factors are volume and pressure.

 
Customized
When the exiting machine number, rotation, the wind angle and transmission mode can not meet the needs of users, we can design according to the fan similar theory and the user's specific parameters requirements.

Technical Support Service
When using our products, If any problems on installation,operation,maintainance..and so on, please contact our sale manager directly or leave a message on our website, we will call you in the first time.

Detailed Performance Catalog
Contact our sales manager to get a list of available fan sizes and to view detailed performance curves for each fan KuangFeng builds.
Specially Designed Fan for Tunnel Ventilation and for Smoke EvacuationsSpecially Designed Fan for Tunnel Ventilation and for Smoke EvacuationsCompany & Brand
KuangFeng brand mine fan have 6 series:XH-MF20/30,XH-CRMF25/35,XH-MLF66/68,XH-MLFD80,XH-RWD/RW/RADW. KuangFeng axial fan are built by Zibo Xinhua Fan Co.,Ltd. in Shandong, China. ZXF has served the mining and tunneling industries for 24 years.Since 1993.
We understand the harsh environments in which fans are used. KuangFeng fans will meet and exceed the demands of your mine or tunnel project.
 
KuangFeng has a wide selection of fans available,has been able to produce more than 200 series, more than 1200 kinds of products.

Warmly welcome factories and various types of mines to choose mine series produced by our company-Zibo Xinhua Fan Co.,Ltd

 
Specially Designed Fan for Tunnel Ventilation and for Smoke Evacuations
Packaging & Shipping

Specially Designed Fan for Tunnel Ventilation and for Smoke Evacuations

FAQ

1.Q: What parameters need to be provided when you design the industrial centrifugal fans?
A: Air flow rate(m3/h), Total pressure(Pa) or Static pressure(Pa), Inlet temperature(°C), Voltage and frequency on the working site.

2. Q:What is your delivery time?
 A:15-35workdays, depending on the model of the fan.

3.Q:Are you manufacturer or trading company?
A:We are the professional manufacturer of centrifugal fans , over 30 years production experience and sales experience.

4.Q:What's your MOQ?
A:The MOQ is 1set,but larger quantity, lower price.

5.Q: What's your warranty?
A: 12 months after arrival of the goods on site.

6.Q:How do you control the product's quality?
A:All the products have quality testing and dynamic balance before delivery

 

Send your message to this supplier

*From:
*To:
avatar Mr. Chen
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Contact Supplier

Gold Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
37
Year of Establishment
1997-11-17