• Direct Drive Centrifugal Fan 22kw
  • Direct Drive Centrifugal Fan 22kw
  • Direct Drive Centrifugal Fan 22kw
  • Direct Drive Centrifugal Fan 22kw
  • Direct Drive Centrifugal Fan 22kw
  • Direct Drive Centrifugal Fan 22kw

Direct Drive Centrifugal Fan 22kw

Material: Iron
Blade Material: Cast Iron
Type: Centrifugal Fan
Electric Current Type: AC
Mounting: Free Standing
Certification: ISO, CE, CCC, Appointed
Customization:
Manufacturer/Factory & Trading Company
Gold Member Since 2017

Suppliers with verified business licenses

Shandong, China
Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (19)
  • Overview
  • Application
  • Company Profile
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
XH
Speed
375/480/580/596/730/745/960/1450/2900r/M
Power Range
2.2-110kw
Flow Range
2065-67803m³/H
Machine No.
6 Machine Number
Pressure Range
742~4483 PA
Color
Blue/Yellow/Green/Customized
Customized
Design and Technical Drawing Can Be Customized
Optional Components
Foundation Bolt/Nuts/Gaskets/Coupling
Transport Package
Strong Wooden Case Exporting Standard
Specification
Adjustable Aluminum Blades
Trademark
Kuang Feng
Origin
China
HS Code
8414599099
Production Capacity
1000sets/Month

Product Description

Direct Drive Centrifugal Fan 22kw
Usage 

XH-BF-17 centrifugal exhaust fan is to burn a variety of coal and with a smoke and dust removal device 1 ton / h -20 tons / h supporting the design of industrial boilers, where the intake conditions are comparable, similar performance can be used , But the maximum temperature shall not exceed 250 ºC, in the induced draft fan must be installed before the dust removal efficiency of not less than 85% of the dust removal device to reduce the smoke into the fan dust content, improve fan life.

Ventilator conveyor medium is the air, the maximum temperature shall not exceed 80 ºC; induced draft fan for the media is flue gas, the maximum temperature shall not exceed
250 ºC.

Dust removal device must be installed in the front of fan to minimize the amount of dust into the fan. According to the usage of general power plants, the efficiency of equipped dust collector shall not be less than 85%.

Direct Drive Centrifugal Fan 22kw
Notes:
When you want to use this series of fans to transport the gas that is flammable, explosive, corrosive or temperature over 80 ºC, we are designed and manufactured for you before your order.
Direct Drive Centrifugal Fan 22kw
Performance Curve&Parameter
Machine NO.

Induced draft mechanism into a single inhalation, machine number has 6: 4,5,6.3,8,10,12.5

As this series Centrifugal exhaust fans have many different machine No and parameters, so if the following spes can't meet your demand,please contact our sales manager to get introduction book or catalog. Thanks for your patience!
 
XH-BF-17№4C Performance Sheet

Speed (r/min) Volume
m3/h
Total Pressure
Pa
Internal
Efficiency
%
Internal
Power
kw
Required Power
kw
Motor
Power
kw
3550 2932
3374
3807
4254
4686
5143
5564
2221
2254
2173
2068
1914
1726
1501
70
74.1
77.2
78.7
77.7
74.4
70
2.57
2.83
2.95
3.08
3.18
3.30
3.30
3.52
3.87
4.04
4.22
4.36
4.51
4.52
5.5
3150 2602
2993
3378
3775
4158
4563
4937
1746
1772
1708
1626
1505
1357
1180
70
74.1
77.2
78.7
77.7
74.4
70
1.80
1.97
2.06
2.15
2.22
2.30
2.31
2.46
2.70
2.82
2.95
3.04
3.15
3.16
4
2800 2313
2661
3003
3355
3696
4056
4388
1377
1398
1348
1283
1188
1071
932
70
74.1
77.2
78.7
77.7
74.4
70
1.26
1.39
1.45
1.51
1.56
1.62
1.62
1.73
1.90
1.98
2.07
2.14
2.21
2.22
3
2500 2065
2376
2681
2996
3300
3622
3918
1097
1113
1073
1022
946
853
742
70
74.1
77.2
78.7
77.7
74.4
70
0.90
0.99
1.03
1.08
1.11
1.15
1.53
1.23
1.35
1.41
1.47
1.52
1.57
1.58
2.2
 
XH-BF-17 №5C Performance Sheet
Speed
r/min
Volume
m3/h
Total Pressure
Pa
Internal Efficiency
%
Internal Power
kw
Required Power
kw
Motor
Power
kw
3150 5304
6062
6820
7578
8336
9093
9851
2819
2793
2737
2592
2406
2175
1913
72
75.9
78.7
80
79.1
76
72
5.71
6.13
6.52
6.76
6.98
7.17
7.22
7.81
8.39
8.92
9.25
9.55
9.81
9.88
11
2800 4715
5389
6062
6736
7409
8083
8757
2223
2203
2158
2044
1898
1716
1509
72
75.9
78.7
80
79.1
76
72
4.01
4.31
4.58
4.75
4.90
5.03
5.07
5.49
5.90
6.27
6.50
6.71
6.89
6.94
7.5
2500 4210
4811
5413
6014
6616
7217
7818
1769
1753
1718
1627
1511
1366
1202
72
75.9
78.7
80
79.1
76
72
2.85
3.07
3.26
3.38
3.49
3.58
3.61
3.90
4.20
4.46
4.62
4.77
4.90
4.94
5.5
2240 3772
4311
4850
5389
5928
6466
7005
1419
1406
1377
1305
1212
1096
964
72
75.9
78.7
80
79.1
76
72
2.05
2.21
2.34
2.43
2.51
2.58
2.60
2.81
3.02
3.21
3.33
3.43
3.53
3.55
4
 
For more differeent machine No and specification,please check other XH-CF-17 series.Please be forgiven if there is any inconveniences occurred.

Ordering instructions

To make the proper fan selection, you must consider the following system conditions the fan will be subjected to:

1. What is the required airflow?
This is rated in cubic feet of air per minute (CFM) or, in metric equivalent, it is rated in cubic meters of air per hour (M³/Hr).

2. What is the static pressure through the complete system?
This is rated in static pressure water gauge (SP) or, in metric equivalent, it is rated in Pascal's (Pa).

3. What is the ambient air temperature outside the fan?

4. What will be the airflow conditions through the fan?

A. Clean or dirty (contaminated) air?
B. Dry or wet (moisture laden) air?
C. Temperature of air?

5. What is the altitude the fan will be operating in?

6. Will the air stream, inside the fan, contain anything that could be explosive or flammable?

7. Will the general location the fan will be operating in contain any type of explosive or flammable material or liquid?

Direct Drive Centrifugal Fan 22kw
Customized
When the exiting machine number, rotation, the wind angle and transmission mode can not meet the needs of users, we can design according to the fan similar theory and the user's specific parameters requirements.

Technical Support Service
When using our centrifugal exhaust fans, If any problems on installation,operation,maintainance..and so on, please contact our sale manager directly or leave a message on our website, we will call you in the first time.

Detailed Performance Catalog
Contact our sales manager to get a list of available fan sizes and to view detailed performance curves for each fan KuangFeng builds.


 
Application

Direct Drive Centrifugal Fan 22kwDirect Drive Centrifugal Fan 22kw

Company Profile
Our company is located in Zhoucun District, Zibo City, Shandong Province. It is adjacent to Bolai Expressway in the east, Zhoucun urban area in the west, Jiqing Expressway in the north, and China National Highway 309. With convenient transportation and superior geography, our company covers an area of 10000 square meters and fixed assets of 50 million yuan.
      The company was founded in 1993 and, after decades of development, has been able to produce over 200 series and over 1200 products, with an annual production capacity of 20 million. The products are widely used in industries such as boilers, workshops, mines, textiles, oil fields, chemicals, kilns, metallurgy, power plants, cement plants, alumina, electrolytic aluminum, building materials, etc. The mining fans, axial flow fans, cotton opening fans, and material conveying fans produced have been inspected by customs and commodity inspection departments and exported to Southeast Asia, Pakistan, Algeria, Kazakhstan, and other countries, deeply favored in the international market.
 
Direct Drive Centrifugal Fan 22kw
Direct Drive Centrifugal Fan 22kw
1. 24*7 hours online service
2.Live video for the workshop by WhatsApp wechat or youtube.
3.Production according to your drawing(2D/3D)
4.High standard quality control- Testing video/Testing report available
5.Welding / Materials testing report available
6.Surface Treatment: automatic electrostatic powder coating ( ie spray) or spray paint.
7.Corrosion protection and rust removal treatment
Packaging & Shipping

Direct Drive Centrifugal Fan 22kw

FAQ
1.Q: What parameters need to be provided when you design the industrial centrifugal fans?
A: Air flow rate(m3/h), Total pressure(Pa) or Static pressure(Pa), Inlet temperature(°C), Voltage and frequency on the working site.

2. Q:What is your delivery time?
 A:15-35workdays, depending on the model of the fan.

3.Q:Are you manufacturer or trading company?
A:We are the professional manufacturer of centrifugal fans , over 30 years production experience and sales experience.

4.Q:What's your MOQ?
A:The MOQ is 1set,but larger quantity, lower price.

5.Q: What's your warranty?
A: 12 months after arrival of the goods on site.

6.Q:How do you control the product's quality?
A:All the products have quality testing and dynamic balance before delivery.

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
37
Year of Establishment
1997-11-17