Resistant Exhaustor Blower Centrifugal Fan for Industrial Ventilation High Temperature Centrifugal Ventilation Fan

Product Details
Customization: Available
Material: Iron
Blade Material: Cast Iron
Manufacturer/Factory & Trading Company
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (20)
  • Resistant Exhaustor Blower Centrifugal Fan for Industrial Ventilation High Temperature Centrifugal Ventilation Fan
  • Resistant Exhaustor Blower Centrifugal Fan for Industrial Ventilation High Temperature Centrifugal Ventilation Fan
  • Resistant Exhaustor Blower Centrifugal Fan for Industrial Ventilation High Temperature Centrifugal Ventilation Fan
  • Resistant Exhaustor Blower Centrifugal Fan for Industrial Ventilation High Temperature Centrifugal Ventilation Fan
  • Resistant Exhaustor Blower Centrifugal Fan for Industrial Ventilation High Temperature Centrifugal Ventilation Fan
  • Resistant Exhaustor Blower Centrifugal Fan for Industrial Ventilation High Temperature Centrifugal Ventilation Fan
Find Similar Products
  • Overview
  • Application
  • Company Profile
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
8-09
Type
Centrifugal Fan
Electric Current Type
AC
Mounting
Free Standing
Certification
ISO, CE, CCC, Appointed
Speed
960/1450/2900r/M
Motor Power
2.2-410kw
Volume
824-63302m³/H
Machine No.
13 Machine Number
Total Pressure
2705~15425 PA
Color
Blue/Yellow/Green/Customized
Keyword
Centrifugal Fans
Application
Industrial Equipment
Blade Angle
25°
Transport Package
Strong Wooden Case Exporting Standard
Specification
Adjustable Aluminum Blades
Trademark
Kuang Feng
Origin
China
HS Code
8414599099
Production Capacity
1000sets/Month

Product Description

Resistant Exhaustor Blower Centrifugal Fan for Industrial Ventilation High Temperature Centrifugal Ventilation Fan
Resistant Exhaustor Blower Centrifugal Fan for Industrial Ventilation High Temperature Centrifugal Ventilation Fan
Resistant Exhaustor Blower Centrifugal Fan for Industrial Ventilation High Temperature Centrifugal Ventilation Fan
Resistant Exhaustor Blower Centrifugal Fan for Industrial Ventilation High Temperature Centrifugal Ventilation Fan
Resistant Exhaustor Blower Centrifugal Fan for Industrial Ventilation High Temperature Centrifugal Ventilation Fan

Usage 

Our Plug Fans are grouped together to form our CENTRIFLOW range.This module without casing looks at centrifugal and axial fans used for ducted ventilation systems/enclosed space and considers selected aspects, including their characteristics and operational attributes.


When you want to use this series of fans to transport the gas that is flammable, explosive, corrosive or temperature over 80 ºC, we are designed and manufactured for you before your order.

Notes:
When you want to use this series of centrifugal extractor fan to transport the gas that is flammable, explosive, corrosive or temperature over 80 ºC, we are designed and manufactured for you before your order.

Parameters
Machine NO.
The fan is for the single-suction type, usually total 13 machine number: 
No 4,4.5,5,5.6,6.3,7.1,8,9,10,11.2,12.5,14,16.

Currently the most frequently used is HCF-19-No5 and No8, HCF-17 No8 and No9.As this series fan have many different machine No and parameters, so if the following spes can't meet your demand,please contact our sales manager to get introduction book or catalog. Thanks for your patience!

HSF-17/19 No 2.8A,3.15A Performance&Parts
  
number transmission
mode
Rotational speed
r/min
Serial Number Export wind speed
Pa
Full pressure
m3/h
Traffic volume
kw
electrical machinery Coupling
GB4323-84
annex
model Power
kw
Bolt

GB799-88
Nut
GB6170-86
Gasket
GB97.1-85
6.8 A 2900 1
2
3
4
5
6
7
10523
11026
11347
11439
11341
11063
10634
675
944
1215
1485
1754
2024
2295
4.62
5.82
7.15
8.63
10.28
11.96
13.60
Y132-2


Y160M1-2

Y160M2-2
7.5


11

15
  M16×400
(4A)
M16(4A) 16(4A)
7.1 D 2900 1
2
3
4
5
6
7
8
11472
12021
12371
12471
12364
12061
11594
11016
768
1075
1383
1690
1997
2304
2612
2919
5.53
6.96
8.71
10.42
12.30
14.35
16.61
18.38
Y132S1-2
Y132S2-2
Y160M1-2

Y160M2-2

Y160L-2
5.5
7.5
11

15

18.5
TL7 M20×500
(6A)
M20(6A) 20(6A)


TL7
8 D 2930 1
2
3
4

5
6
7
8
14867
15579
16033
16163

16023
15632
15026
14277
1110
1554
1998
2442

2887
3331
3775
4219
10.36
13.04
16.31
19.51

23.04
26.88
31.11
34.43
Y160M1-2
Y160M2-2
Y160L-2
Y180M-2

Y200L1-2

Y200L2-2
11
15
18.5
22

30

37
TL7 M20×500
(6A)
M20(6A) 20(6A)
TL7
TL7
8.5 D 2950 1
2
3
4
5
6
7
8
17013
17828
18347
18496
18338
17888
17196
(16339)
1341
1877
2414
2950
3487
4023
4560
(5096)
14.32
18.02
22.54
26.97
31.85
37.15
43.00
(47.59)
Y160M2-2
Y160L-2
Y200L1-2

Y200L2-2
Y225M-2
15
18.5
30

37
45
TL7 M20×500
(8A)
M20(8A) 20(8A)
TL7
     
9 D 2950 1



2
3
4

5
6
7
8
19073



19988
20569
20736

20558
20054
19278
18318
1591



2228
2865
3502

4138
4775
5412
6049
19.05



23.98
30.00
35.90

42.37
49.44
57.22
63.33
Y180M-2



Y200L1-2

Y200L2-2

Y225M-2
Y250M-2
Y280S-2
22



30

37

45
55
75
TL7 M12×300
(4A)
M20×500
(4A)
M12(4A)
M20(4A)
12(4A)
20(4AA)
TL7 M16×400
(4A)
M20×500
(4A)
M16(4AA)
M20(4A)
16(4A)
20(4A)
TL8 M20×500
(8A)
M20(8A) 20(8A)
TL8
6.8 A 2930 1
2
3
4
5
6
78
11590
11820
12000
12140
12120
11980
11740
1700
2160
2620
3080
3540
4000
4460
9.32
11.59
13.57
15.93
18.27
20.55
22.60
Y160M2-2


Y160L-2

Y180M-2
15


18.5

22
  M16×400
(4A)
M16(4A) 16(4A)
7.1 A 2900 1
2
3
4
5
6
7
12347
12661
12807
12896
13024
12935
12739
2074
2658
3000
3242
3826
4410
4990
12.10
15.02
16.43
18.02
21.14
24.30
27.65
Y160M2-2

Y160L-2

Y180M-2
Y200L1-2
15

18.5

22
30
  M16×400
(4A)
M16(4A) 16(4A)
7.4 D 2900 1
2
3

4
5
6
7
13416
13749
14004

14142
14053
13838
13465
2349
3010
3371

4332
4993
5654
6315
14.88
18.47
22.16

25.99
29.89
33.99
38.07
Y160M2-2
Y160L-2
Y180M-2

Y200L1-2

Y200L2-2
Y225M-2
15
18.5
22

30

37
45
TL7 M12×300 M12 12
                  TL7      
                  TL7 M16×400 M16 16
7.7 A 2930 1
2
3
4
5
6
7
14543
14887
15171
15319
15220
14985
14583
2349
3010
3671
4332
4993
5654
6315
15.81
19.60
23.52
27.59
31.72
36.07
40.40
Y180M-2

Y200L1-2

Y200L2-2

Y225M-2
22

30

37

45
  M16×400(4A)
M20×500(4A)
M16(4A)
M20(4A)
16(4A)
20(4A)
8 D 2950 1
2
3
4
5
6
16216
16528
16931
17096
16931
16729
2996
3824
4651
5478
6306
7133
22.97
28.24
33.98
39.78
45.52
51.83
Y200L1-2

Y200L2-2
Y225M-2

Y250M-2
30

37
45

55
TL7 M16×400(4A) M16(4A) 16(4A)
                  TL8 M20×500(8A) M20(8A) 20(8A)
      7 (16216) (7960) (57.84)            
9 D 2970 1

2

3
4
5
20803

21202

21719
21931
21719
4295

5481

6667
7853
9039
42.24

51.93

62.48
73.15
83.71
Y225M-2

Y250M-2

Y280S-2

Y280M-2
45

55

75

90
TL8 M16×400(4A)
M20×500(4A)
M16(4A)
M20(4A)
16(4A)
20(4A)
                  TL8 M20×500(8A) M20(8A) 20(8A)
                  TL8      
      6
7
(21461)
(20808)
(10225)
(11411))
(95.31)
(106.40)
           



For more differeent machine No and specification,please check other XH-CF-13 series.Please be forgiven if there is any inconveniences occurred.
Resistant Exhaustor Blower Centrifugal Fan for Industrial Ventilation High Temperature Centrifugal Ventilation Fan
Ordering instructions

To make the proper fan selection, you must consider the following system conditions the fan will be subjected to:

1. What is the required airflow?
This is rated in cubic feet of air per minute (CFM) or, in metric equivalent, it is rated in cubic meters of air per hour (M³/Hr).

2. What is the static pressure through the complete system?
This is rated in static pressure water gauge (SP) or, in metric equivalent, it is rated in Pascal's (Pa).

3. What is the ambient air temperature outside the fan?

4. What will be the airflow conditions through the fan?

1.    Clean or dirty (contaminated) air?

2.    Dry or wet (moisture laden) air?

3.    Temperature of air?

5. What is the altitude the fan will be operating in?

6. Will the air stream, inside the fan, contain anything that could be explosive or flammable?

7. Will the general location the fan will be operating in contain any type of explosive or flammable material or liquid?

Customized
When the exiting machine number, rotation, the wind angle and transmission mode can not meet the needs of users, we can design according to the fan similar theory and the user's specific parameters requirements.

Technical Support Service
When using our centrifugal extractor fan, If any problems on installation,operation,maintainance..and so on, please contact our sale manager directly or leave a message on our website, we will call you in the first time.

Detailed Performance Catalog
Contact our sales manager to get a list of available fan sizes and to view detailed performance curves for each fan KuangFeng builds.
 
Application

Resistant Exhaustor Blower Centrifugal Fan for Industrial Ventilation High Temperature Centrifugal Ventilation Fan

Resistant Exhaustor Blower Centrifugal Fan for Industrial Ventilation High Temperature Centrifugal Ventilation Fan
Company Profile
Our company is located in Zhoucun District, Zibo City, Shandong Province. It is adjacent to Bolai Expressway in the east, Zhoucun urban area in the west, Jiqing Expressway in the north, and China National Highway 309. With convenient transportation and superior geography, our company covers an area of 10000 square meters and fixed assets of 50 million yuan.
      The company was founded in 1993 and, after decades of development, has been able to produce over 200 series and over 1200 products, with an annual production capacity of 20 million. The products are widely used in industries such as boilers, workshops, mines, textiles, oil fields, chemicals, kilns, metallurgy, power plants, cement plants, alumina, electrolytic aluminum, building materials, etc. The mining fans, axial flow fans, cotton opening fans, and material conveying fans produced have been inspected by customs and commodity inspection departments and exported to Southeast Asia, Pakistan, Algeria, Kazakhstan, and other countries, deeply favored in the international market.
 
Resistant Exhaustor Blower Centrifugal Fan for Industrial Ventilation High Temperature Centrifugal Ventilation Fan
Resistant Exhaustor Blower Centrifugal Fan for Industrial Ventilation High Temperature Centrifugal Ventilation Fan
Resistant Exhaustor Blower Centrifugal Fan for Industrial Ventilation High Temperature Centrifugal Ventilation Fan
1. 24*7 hours online service
2.Live video for the workshop by WhatsApp wechat or youtube.
3.Production according to your drawing(2D/3D)
4.High standard quality control- Testing video/Testing report available
5.Welding / Materials testing report available
6.Surface Treatment: automatic electrostatic powder coating ( ie spray) or spray paint.
7.Corrosion protection and rust removal treatment
Packaging & Shipping

Resistant Exhaustor Blower Centrifugal Fan for Industrial Ventilation High Temperature Centrifugal Ventilation Fan

FAQ

1.Q: What parameters need to be provided when you design the industrial centrifugal fans?
A: Air flow rate(m3/h), Total pressure(Pa) or Static pressure(Pa), Inlet temperature(°C), Voltage and frequency on the working site.

2. Q:What is your delivery time?
 A:15-35workdays, depending on the model of the fan.

3.Q:Are you manufacturer or trading company?
A:We are the professional manufacturer of centrifugal fans , over 30 years production experience and sales experience.

4.Q:What's your MOQ?
A:The MOQ is 1set,but larger quantity, lower price.

5.Q: What's your warranty?
A: 12 months after arrival of the goods on site.

6.Q:How do you control the product's quality?
A:All the products have quality testing and dynamic balance before delivery.

 

 electrical machinerymodelelectrical machineryannex

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier