Y4-73-18d-110kw Centrifugal Boiler Draft Fan and Various Types of Impeller

Product Details
Customization: Available
Material: Iron
Flow Direction: Centrifugal
Manufacturer/Factory & Trading Company
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (20)
  • Y4-73-18d-110kw Centrifugal Boiler Draft Fan and Various Types of Impeller
  • Y4-73-18d-110kw Centrifugal Boiler Draft Fan and Various Types of Impeller
  • Y4-73-18d-110kw Centrifugal Boiler Draft Fan and Various Types of Impeller
  • Y4-73-18d-110kw Centrifugal Boiler Draft Fan and Various Types of Impeller
  • Y4-73-18d-110kw Centrifugal Boiler Draft Fan and Various Types of Impeller
  • Y4-73-18d-110kw Centrifugal Boiler Draft Fan and Various Types of Impeller
Find Similar Products
  • Overview
  • Application
  • Company Profile
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
XH-BF-14
Pressure
High Pressure
Certification
ISO, CE, CCC, Appointed
Speed
375/480/580/596/730/745/960/1450/2900r/M
Power Range
5.5-1600kw
Flow Range
15229-810000m³/H
Machine No.
13 Machine Number
Pressure Range
343~7218 PA
Color
Blue/Yellow/Green/Customized
Customized
Design and Technical Drawing Can Be Customized
Accessory
Foundation Bolt/Nuts/Gaskets
Optional Components
Foundation Bolt/Nuts/Gaskets/Coupling
Transport Package
Strong Wooden Case Exporting Standard
Specification
Adjustable Aluminum Blades
Trademark
Kuang Feng
Origin
China
HS Code
8414599099
Production Capacity
1000sets/Month

Product Description

Y4-73-18d-110kw Centrifugal Boiler Draft Fan and Various Types of Impeller
Usage 
XH-BF-14 boiler pass, Industrial Centrifugal Fans is mainly applicable to the ventilation system for 2-670t / h steam boiler in thermal power plant. The XH-BF-14 series can also be used in mine ventilation and general ventilation without other special requirements required.

Ventilator conveyor medium is the air, the maximum temperature shall not exceed 80 ºC; induced draft fan for the media is flue gas, the maximum temperature shall not exceed
250 ºC.

Dust removal device must be installed in the front of fan to minimize the amount of dust into the fan. According to the usage of general power plants, the efficiency of equipped dust collector shall not be less than 85%.

Y4-73-18d-110kw Centrifugal Boiler Draft Fan and Various Types of Impeller
Notes:
When you want to use this series of fans to transport the gas that is flammable, explosive, corrosive or temperature over 80 ºC, we are designed and manufactured for you before your order.
Y4-73-18d-110kw Centrifugal Boiler Draft Fan and Various Types of Impeller
Performance Curve&Parameter
Machine NO.

Ventilator and induced draft fan are made of single inhalation, each with total 13 machine number from № 8 to 29.5.

As this series fan have many different machine No and parameters, so if the following spes can't meet your demand,please contact our sales manager to get introduction book or catalog. Thanks for your patience!
 
XH-BF-14 Centrifugal Fan Performance
Machine No. Drive Mode Speed r/min Volume m3/h Total PressurePa  Internal Efficiency  % Internal Power  kw Power  kw Motor
Power(kw)
8 D 1450 16156 2104 79.4 11.8 13.85 18.5
18244 2095 83.2 12.67 14.86
20442 2072 85.7 13.63 15.99
22530 2018 87 14.42 16.92
24618 1924 86.8 15.06 17.67
26706 1794 85.6 15.45 18.13
28904 1611 82.8 15.53 18.22
30993 1400 79.4 15.11 17.73
9 D 1450 23003 2668 79.4 21.27 24.96 30
25976 2656 83.2 22.83 26.78
29106 2628 85.7 24.55 28.81
32079 2559 87 2598 30.48
35052 2440 86.8 27.13 31.84
38026 2275 85.6 27.84 32.67
41155 2042 82.8 27.99 32.84
44128 1775 79.4 27.23 31.95 37
9 D 960 15229 1163 79.4 6.17 7.24 11
17198 1158 83.2 6.62 7.77
19270 1146 85.7 7.13 8.36
21238 1116 87 7.54 8.85
23207 1064 86.8 7.87 9.24
25175 993 85.6 8.08 9.48
27247 891 82.8 8.12 9.53
29216 775 79.4 7.9 9.27
10 D 1450 31554 3301 79.4 36.02 42.27 55
35633 3287 83.2 38.66 45.36
39926 3251 85.7 41.58 48.79
44004 3166 87 44 51.64
48083 3018 86.8 45.95 53.92
52161 2813 85.6 47.15 55.32
56455 2525 82.8 47.39 55.61
60533 2194 79.4 46.12 54.11
 
BF-14 No 10D,11D Performance
Machine No. Drive Mode Speed
r/min
Volume
m3/h
Total Pressure
Pa
Internal
Efficiency
%
Internal Power
kw
Required Power
kw
Motor
Power
kw
10 D 960 20891
23591
26434
29134
31834
34534
37377
40077
1437
1431
1416
1379
1315
1226
1101
958
79.4
83.2
85.7
87
86.8
85.6
82.8
79.4
10.45
11.22
12.07
12.76
13.34
13.68
13.75
13.38
12.26
13.16
14.16
14.98
15.65
16.06
16.14
15.70
15
18.5
10 D 730 15886
17939
20100
22154
24207
26260
28422
30475
829
826
817
796
759
708
636
553
79.4
83.2
85.7
87
86.8
85.6
82.8
79.4
4.60
4.93
55.31
5.61
5.86
6.02
6.05
5.88
5.63
7.79
6.23
6.59
6.88
7.06
7.10
6.91
7.5
11 D 1450 41999
47427
53142
58570
63998
69427
75141
80570
4003
3986
3943
3840
3660
3411
3060
2659
79.4
83.2
85.7
87
86.8
85.6
82.8
79.4
58.01
62.26
66.87
70.88
74.00
85.93
76.33
74.27
68.07
73.05
78.58
83.16
86.84
89.10
89.57
87.15
75
90
11 D 960 27806
31400
35183
38777
42371
45965
49748
53343
1741
1734
1715
1671
1593
1485
1334
1160
79.4
83.2
85.7
87
86.8
85.6
82.8
79.4
16.83
18.07
19.43
20.57
21.48
22.04
22.15
21.55
19.75
21.20
22.80
24.13
25.20
25.86
25.99
25.29
22
30
Y4-73-18d-110kw Centrifugal Boiler Draft Fan and Various Types of Impeller
For more differeent machine No and specification,please check other XH-CF-13 series.Please be forgiven if there is any inconveniences occurred.

Ordering instructions
When ordering, please specify the fan number, speed, air volume, wind pressure, outlet angle and direction of rotation, as well as motor model, power, speed and so on.
The most important factors are volume and pressure.
Y4-73-18d-110kw Centrifugal Boiler Draft Fan and Various Types of Impeller
Customized
When the exiting machine number, rotation, the wind angle and transmission mode can not meet the needs of users, we can design according to the fan similar theory and the user's specific parameters requirements.
 
Application

Y4-73-18d-110kw Centrifugal Boiler Draft Fan and Various Types of ImpellerY4-73-18d-110kw Centrifugal Boiler Draft Fan and Various Types of Impeller

Company Profile

Our company is located in Zhoucun District, Zibo City, Shandong Province. It is adjacent to Bolai Expressway in the east, Zhoucun urban area in the west, Jiqing Expressway in the north, and China National Highway 309. With convenient transportation and superior geography, our company covers an area of 10000 square meters and fixed assets of 50 million yuan.
      The company was founded in 1993 and, after decades of development, has been able to produce over 200 series and over 1200 products, with an annual production capacity of 20 million. The products are widely used in industries such as boilers, workshops, mines, textiles, oil fields, chemicals, kilns, metallurgy, power plants, cement plants, alumina, electrolytic aluminum, building materials, etc. The mining fans, axial flow fans, cotton opening fans, and material conveying fans produced have been inspected by customs and commodity inspection departments and exported to Southeast Asia, Pakistan, Algeria, Kazakhstan, and other countries, deeply favored in the international market.
Y4-73-18d-110kw Centrifugal Boiler Draft Fan and Various Types of ImpellerY4-73-18d-110kw Centrifugal Boiler Draft Fan and Various Types of Impeller

1. 24*7 hours online service
2.Live video for the workshop by WhatsApp wechat or youtube.
3.Production according to your drawing(2D/3D)
4.High standard quality control- Testing video/Testing report available
5.Welding / Materials testing report available
6.Surface Treatment: automatic electrostatic powder coating ( ie spray) or spray paint.
7.Corrosion protection and rust removal treatment

 
Packaging & Shipping

Y4-73-18d-110kw Centrifugal Boiler Draft Fan and Various Types of Impeller

FAQ

1.Q: What parameters need to be provided when you design the industrial centrifugal fans?
A: Air flow rate(m3/h), Total pressure(Pa) or Static pressure(Pa), Inlet temperature(°C), Voltage and frequency on the working site.

2. Q:What is your delivery time?
 A:15-35workdays, depending on the model of the fan.

3.Q:Are you manufacturer or trading company?
A:We are the professional manufacturer of centrifugal fans , over 30 years production experience and sales experience.

4.Q:What's your MOQ?
A:The MOQ is 1set,but larger quantity, lower price.

5.Q: What's your warranty?
A: 12 months after arrival of the goods on site.

6.Q:How do you control the product's quality?
A:All the products have quality testing and dynamic balance before delivery.


 