Usage
XH-BF-12 boiler blower is mainly used in 2t / h ~ 670t / h steam boiler ventilation in the thermal power plant, and it can also meet the high pressure head performance parameters of fluidized bed furnace. This series fans can also be used for dust, mine fan General ventilation system
XH-BF-12 boiler blower is for 35t / h ~ 410t / h circulating fluidized bed boiler feed system, the system fan can also be used for dust, mine ventilation and general ventilation system.
The medium for the blower is air, and the medium for the draft fan is flue gas or particulate matter containing impurities. If the impurity concentration is less than 200mg / m3, the impeller can be used for more than five years. If the impurity is large, the service life is shortened and the maximum temperature of the blower can not exceed 250 ºC.

Model Series
XH-BF-12 type fans have total 20 machine No. and 40 specification, from No.8D~29.5D
Parameters
BF-12 Performance&Parts
Here's part of parameters.
More specification please contact us to get latest catalog and performance curve.
Machine
No. |
Speed
r/min |
Total
Pressure
Pa |
Volume
m3/h |
Internal Efficiency
% |
Internal
Power
kw |
Shaft Power
kw |
Required
Power
kw |
Motor |
Power
kw |
8D |
1450 |
2745
2701
2612
2479
2346
2214
2036
1859 |
11000
13200
15400
17600
19800
22000
24200
26400 |
75
78
81
83
82
80
77
74 |
11.2
12.7
13.8
14.6
15.7
16.9
17.8
18.4 |
11.4
13
14.1
14.8
16.1
17.3
18.1
18.8 |
13.1
14.9
16.2
17
18.5
19.8
20.9
21.6 |
15 |
18.5 |
22 |
9D |
1450 |
3474
3418
3306
3138
2969
2801
2577
2353 |
15700
18800
21900
25000
28100
31300
34400
37500 |
75
78
81
83
82
80
77
74 |
20.2
22.9
24.8
26.3
28.3
30.4
32
33.1 |
20.6
23.4
25.3
26.8
28.8
31.1
32.6
33.8 |
23.7
26.9
29.1
30.8
33.2
35.7
37.5
38.9 |
30 |
45 |
10D |
1450 |
4289
4220
4081
3874
3666
3459
3182
2905 |
21500
25800
30000
34300
38600
42900
47200
51500 |
75
78
81
83
82
80
77
74 |
34.2
38.8
42
44.5
47.9
51.5
54.2
56.2 |
34.9
39.6
42.8
45.4
48.9
52.6
55.3
57.3 |
40.1
45.5
49.3
52.2
56.3
60.5
63.6
65.9 |
45 |
55 |
75 |
11D |
1450 |
5190
5106
4938
4688
4436
4185
3850
3515 |
28600
34300
40000
45700
51400
57100
62800
68500 |
75
78
81
83
82
80
77
74 |
55
62
68
72
77
83
87
90 |
56
64
69
73
79
85
89
92 |
65
73
79
84
91
97
102
106 |
75 |
90 |
110 |
Machine No. |
Speed
r/min |
Total Pressure
Pa |
Capacity
m3/h |
Internal Efficiency
% |
Internal Power
kw |
Shaft Power
kw |
Required Power
kw |
Motor |
Power
kw |
11D |
960 |
2275
2238
2164
2055
1944
1834
1688
1541 |
18900
22700
26500
30300
34000
37800
41600
45400 |
75
78
81
83
82
80
77
74 |
15.9
18.1
19.7
20.8
22.4
24.1
25.3
26.3 |
16.3
18.5
20.1
21.3
22.8
24.6
25.8
26.8 |
18.7
21.2
23.1
24.5
26.3
28.2
29.7
30.8 |
22 |
30 |
12D |
1450 |
6176
6077
5877
5579
5279
4981
4582
4183 |
37100
44600
51800
59300
66700
74100
81600
89000 |
75
78
81
83
82
80
77
74 |
85
97
104
111
119
128
135
140 |
87
98
107
113
122
131
138
143 |
100
113
123
130
140
150
158
164 |
110 |
132 |
160 |
12D |
960 |
2707
2664
2576
2445
2314
2183
2008
1834 |
24600
29500
34300
39300
44200
49100
54100
59000 |
75
78
81
83
82
80
77
74 |
24.7
28
30.3
32.2
34.6
37.2
39.2
40.6 |
25.2
28.6
30.9
32.8
35.4
38
40
41.4 |
28.9
32.8
35.6
37.7
40.7
43.7
46
47.7 |
37 |
45 |
55 |
13D |
1450 |
7248
7132
6897
6547
6196
5846
5378
4909 |
47200
56700
65900
75400
84800
94300
104000
113000 |
75
78
81
83
82
80
77
74 |
127
144
156
165
178
191
202
208 |
129
147
159
169
182
195
206
212 |
149
169
183
194
209
225
237
244 |
185 |
200 |
250 |
Complete sets of supply
1, A fan
2, Foundation bolts 1 set
3, Coupling guard 1 set
4,Thermometer 8-16 for the two bimetallic live contact thermometer, 17-31.5F2 only bimetallic thermometer and two platinum thermal resistance.
5, Outlet and inlet soft connection.
6, The motor (without electrical equipment) one (subject to the contract)
Ordering instructions
When ordering, please specify the fan number, speed, air volume, wind pressure, outlet angle and direction of rotation, as well as motor model, power, speed and so on.
The most important factors are volume and pressure.
Customized
When the exiting machine number, rotation, the wind angle and transmission mode can not meet the needs of users, we can design according to the fan similar theory and the user's specific parameters requirements.
Technical Support Service
When using our products, If any problems on installation,operation,maintainance..and so on, please contact our sale manager directly or leave a message on our website, we will call you in the first time.
Detailed Performance Catalog
Contact our sales manager to get a list of available fan sizes and to view detailed performance curves for each fan KuangFeng builds.
Application


Company Profile
Our company is located in Zhoucun District, Zibo City, Shandong Province. It is adjacent to Bolai Expressway in the east, Zhoucun urban area in the west, Jiqing Expressway in the north, and China National Highway 309. With convenient transportation and superior geography, our company covers an area of 10000 square meters and fixed assets of 50 million yuan.
The company was founded in 1993 and, after decades of development, has been able to produce over 200 series and over 1200 products, with an annual production capacity of 20 million. The products are widely used in industries such as boilers, workshops, mines, textiles, oil fields, chemicals, kilns, metallurgy, power plants, cement plants, alumina, electrolytic aluminum, building materials, etc. The mining fans, axial flow fans, cotton opening fans, and material conveying fans produced have been inspected by customs and commodity inspection departments and exported to Southeast Asia, Pakistan, Algeria, Kazakhstan, and other countries, deeply favored in the international market.
1. 24*7 hours online service
2.Live video for the workshop by WhatsApp wechat or youtube.
3.Production according to your drawing(2D/3D)
4.High standard quality control- Testing video/Testing report available
5.Welding / Materials testing report available
6.Surface Treatment: automatic electrostatic powder coating ( ie spray) or spray paint.
7.Corrosion protection and rust removal treatment
Packaging & Shipping

FAQ
1.Q: What parameters need to be provided when you design the industrial centrifugal fans?
A: Air flow rate(m3/h), Total pressure(Pa) or Static pressure(Pa), Inlet temperature(°C), Voltage and frequency on the working site.
2. Q:What is your delivery time?
A:15-35workdays, depending on the model of the fan.
3.Q:Are you manufacturer or trading company?
A:We are the professional manufacturer of centrifugal fans , over 30 years production experience and sales experience.
4.Q:What's your MOQ?
A:The MOQ is 1set,but larger quantity, lower price.
5.Q: What's your warranty?
A: 12 months after arrival of the goods on site.
6.Q:How do you control the product's quality?
A:All the products have quality testing and dynamic balance before delivery.