Machine NO.
The fan is for the single-suction type, usually total 13 machine number:Machine No |
Driven Mode | Speed r/min |
No | Total Pressure Pa |
Volume m3/h |
Internal Efficiency % |
Internal Power KW |
Required Power KW |
Motor |
Power KW |
|||||||||
4 | A | 2900 | 1 | 3893 | 2198 | 81.5 | 2.92 | 3.35 | 4 |
2 | 3884 | 2473 | 82.6 | 3.23 | 3.71 | ||||
3 | 3835 | 2748 | 82.6 | 3.54 | 4.07 | 5.5 | |||
4 | 3776 | 3022 | 82.0 | 3.86 | 4.44 | ||||
5 | 3707 | 3297 | 81.1 | 4.18 | 4.81 | ||||
6 | 3629 | 3572 | 80.0 | 4.50 | 5.17 | 7.5 | |||
7 | 3540 | 3847 | 78.3 | 4.83 | 5.55 | ||||
8 | 3452 | 4122 | 76.4 | 5.17 | 5.95 | ||||
4.5 | A | 2900 | 1 | 4933 | 3130 | 81.5 | 5.26 | 6.05 | 7.5 |
2 | 4623 | 3521 | 82.6 | 5.83 | 6.70 | ||||
3 | 4854 | 3912 | 82.6 | 6.38 | 7.34 | 11 | |||
4 | 4776 | 4303 | 82.0 | 6.96 | 8.00 | ||||
5 | 4698 | 4695 | 81.1 | 7.55 | 8.68 | ||||
6 | 4599 | 5086 | 80.0 | 8.12 | 9.34 | ||||
7 | 4482 | 5477 | 78.3 | 8.71 | 10.01 | ||||
8 | 4374 | 5868 | 76.4 | 9.33 | 10.73 | ||||
5 | A | 2900 | 1 | 6090 | 4293 | 81.5 | 8.91 | 10.24 | 15 |
2 | 6071 | 4830 | 82.6 | 9.86 | 11.34 | ||||
3 | 6002 | 5367 | 82.6 | 10.83 | 12.45 | ||||
4 | 5894 | 5903 | 82.0 | 11.78 | 13.55 | ||||
5 | 5796 | 6440 | 81.1 | 12.78 | 14.70 | ||||
6 | 5678 | 6977 | 80.0 | 13.75 | 15.81 | 18.5 | |||
7 | 5531 | 7513 | 78.3 | 14.74 | 16.95 | ||||
8 | 5394 | 8050 | 76.4 | 15.78 | 18.15 | ||||
5.6 | A | 2900 | 1 | 7640 | 6032 | 81.5 | 15.70 | 18.06 | 22 |
2 | 7620 | 6786 | 82.6 | 17.38 | 19.99 | ||||
3 | 7522 | 7540 | 82.6 | 19.07 | 21.93 | 30 | |||
4 | 7394 | 8294 | 82.0 | 20.77 | 23.88 | ||||
5 | 7277 | 048 | 81.1 | 22.54 | 25.93 | ||||
6 | 7120 | 9802 | 80.0 | 24.22 | 27.86 | 37 | |||
7 | 6943 | 10555 | 78.3 | 25.99 | 29.89 | ||||
8 | 6767 | 11309 | 76.4 | 27.81 | 31.99 |
Machine No. | Driven Mode | Speed r/min |
No | Total Pressure Pa |
Volume m3/h |
Internal Efficiency % |
Internal Pwoer KW |
Required Power KW |
Motor |
Power KW |
|||||||||
6.3 | A | 2900 | 1 | 9670 | 8558 | 81.5 | 28.29 | 32.54 | 45 |
2 | 9610 | 9662 | 82.6 | 31.31 | 36.01 | ||||
3 | 9523 | 10735 | 82.6 | 34.37 | 39.52 | 55 | |||
4 | 9356 | 11809 | 82.0 | 37.41 | 43.03 | ||||
5 | 9209 | 12882 | 81.1 | 40.62 | 46.71 | ||||
6 | 9003 | 13956 | 80.0 | 43.61 | 50.15 | 75 | |||
7 | 8787 | 15029 | 78.3 | 46.84 | 53.86 | ||||
8 | 8571 | 16103 | 76.4 | 50.17 | 57.69 |
Machine No |
Driven Mode | Speed r/min |
No. | Total Pressure Pa |
Volume m3/h |
Internal Efficiency % |
Internal Pwoer KW |
Required Power KW |
Motor | |
Power KW |
||||||||||
7.1 | D | 2900 | 1 | 12278 | 12293 | 81.5 | 51.43 | 60.35 | 75 | |
2 | 12249 | 13829 | 82.6 | 56.95 | 66.83 | |||||
3 | 12092 | 15366 | 82.6 | 62.47 | 73.30 | |||||
4 | 11886 | 16903 | 82.0 | 68.04 | 79.84 | 110 | ||||
5 | 11690 | 18439 | 81.1 | 73.81 | 86.61 | |||||
6 | 11445 | 19976 | 80.0 | 79.36 | 73.13 | |||||
7 | 11160 | 21512 | 78.3 | 85.14 | 99.92 | |||||
8 | 10886 | 23049 | 76.4 | 91.20 | 107.02 | |||||
8 | D | 2900 | 1 | 15583 | 17585 | 81.5 | 93.37 | 109.57 | 132 | |
2 | 15554 | 19783 | 82.6 | 103.45 | 121.39 | |||||
3 | 15358 | 21981 | 82.6 | 113.49 | 133.18 | |||||
4 | 15093 | 24180 | 82.0 | 123.59 | 145.03 | 200 | ||||
5 | 14848 | 26378 | 81.1 | 134.10 | 157.37 | |||||
6 | 14524 | 28576 | 80.0 | 144.07 | 169.06 | |||||
7 | 14171 | 30774 | 78.3 | 154.66 | 181.50 | |||||
8 | 13818 | 32972 | 76.4 | 165.60 | 194.33 |
To make the proper fan selection, you must consider the following system conditions the fan will be subjected to:
1. What is the required airflow?
This is rated in cubic feet of air per minute (CFM) or, in metric equivalent, it is rated in cubic meters of air per hour (M³/Hr).
2. What is the static pressure through the complete system?
This is rated in static pressure water gauge (SP) or, in metric equivalent, it is rated in Pascal's (Pa).
3. What is the ambient air temperature outside the fan?
4. What will be the airflow conditions through the fan?
1. Clean or dirty (contaminated) air?
2. Dry or wet (moisture laden) air?
3. Temperature of air?
5. What is the altitude the fan will be operating in?
6. Will the air stream, inside the fan, contain anything that could be explosive or flammable?
7. Will the general location the fan will be operating in contain any type of explosive or flammable material or liquid?
1.Q: What parameters need to be provided when you design the industrial centrifugal fans?
A: Air flow rate(m3/h), Total pressure(Pa) or Static pressure(Pa), Inlet temperature(°C), Voltage and frequency on the working site.
2. Q:What is your delivery time?
A:15-35workdays, depending on the model of the fan.
3.Q:Are you manufacturer or trading company?
A:We are the professional manufacturer of centrifugal fans , over 30 years production experience and sales experience.
4.Q:What's your MOQ?
A:The MOQ is 1set,but larger quantity, lower price.
5.Q: What's your warranty?
A: 12 months after arrival of the goods on site.
6.Q:How do you control the product's quality?
A:All the products have quality testing and dynamic balance before delivery.