Sdf Tunnel Construction Axial Flow Fan Adjusted Tunnel Jet Fan

Product Details
Customization: Available
Material: Iron
Usage: Ventilation
Manufacturer/Factory & Trading Company
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (20)
  • Sdf Tunnel Construction Axial Flow Fan Adjusted Tunnel Jet Fan
  • Sdf Tunnel Construction Axial Flow Fan Adjusted Tunnel Jet Fan
  • Sdf Tunnel Construction Axial Flow Fan Adjusted Tunnel Jet Fan
  • Sdf Tunnel Construction Axial Flow Fan Adjusted Tunnel Jet Fan
  • Sdf Tunnel Construction Axial Flow Fan Adjusted Tunnel Jet Fan
  • Sdf Tunnel Construction Axial Flow Fan Adjusted Tunnel Jet Fan
Find Similar Products
  • Overview
  • Product Parameters
  • Products Real Shot
  • Application
  • Company Profile
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
XH
Flow Direction
Axial Flow
Pressure
Low Pressure
Certification
ISO, CE, CCC, Appointed
Speed
490/590/740/980r/M
Power
2*55-2*1250kw
Volume
10.1-462.1m³/S
Machine No.
9 Machine Number
Total Pressure
559~6921 PA
Color
Red/Yellow/Customized
Customized
Design and Technical Drawing Can Be Customized
Voltage
330V/660V
Weight
6675-185583
Motor Qty
2
Transport Package
Strong Wooden Case Exporting Standard
Trademark
Kuang Feng
Origin
China
HS Code
8414599099
Production Capacity
1000sets/Month

Product Description

Sdf Tunnel Construction Axial Flow Fan Adjusted Tunnel Jet Fan
RADW series fan is a large-scale explosion-proof axial fan for mine developed by combining the parameters of ventilation network for mine. It's with the advantages of high efficiency, energy saving and low noise. The static pressure efficiency of the product can reach above 86%, and the main fan achieved the leading level in China. The adopt explosion-proof material passed the test center of the friction spark test and reached the explosion-proof requirements. This material is approved by Chinese Academy of Sciences Chongqing Branch.the whole explosion-proof performance has passed explosion-proof test by the national explosion-proof electrical product quality testing center.
Sdf Tunnel Construction Axial Flow Fan Adjusted Tunnel Jet Fan
Product Parameters
Series No. Volume
(m³/s)
Total Pressure
(Pa)
Power
(KW)
Weight
(kg)
RADW
  (A)
-6-NO
(n=980r/min)
14 10.1~31.7 918~2888 2×55 6675
15 12.4~39.0 1054~3315 2×75 7896
16 15.0~47.3 1199~3772 2×110 9090
17 18.0~56.8 1353~4258 2×132 10178
18 21.4~67.4 1517~4774 2×185 12240
19 25.1~79.3 1690~5319 2×220 17235
20 29.3~92.5 1873~5893 2×250 18855
21 33.9~107.0 2065~6497 2×355 22866
RADW
  (A)
-8-NO
(n=740r/min)
17 13.6~42.9 772~2428 2×55 9618
18 16.1~50.9 865~2722 2×75 10920
19 19.0~60.0 964~3033 2×110 15555
20 22.1~69.8 1068~3360 2×132 17635
21 25.6~80.8 1177~3705 2×160 19466
22 29.5~92.9 1292~4066 2×200 21769
23 33.7~106.2 1412~4444 2×250 25784
24 38.2~120.7 1538~4839 2×315 32938
25 43.2~136.4 1669~5250 2×315 35136
26 48.6~153.4 1805~5679 2×450 41234
27 54.4~171.8 1946~6124 2×450 43701
28 60.7~191.6 2093~6586 2×710 49069
RADW
  (A)
-10-NO
(n=590r/min)
20 17.6~55.7 679~2136 2×75 16555
21 20.4~64.4 748~2355 2×90 18426
22 23.5~74.1 821~2585 2×110 20649
23 26.8~84.7 898~2825 2×132 22624
24 30.5~96.2 978~3076 2×160 30038
25 34.5~108.7 1061~3338 2×185 32436
26 38.8~122.3 1147~3610 2×250 37334
27 43.4~137.0 1237~3893 2×250 39801
28 48.4~152.8 1331~4187 2×315 48909
29 53.8~169.7 1427~4491 2×355 60771
30 59.5~187.9 1527~4806 2×450 67447
32 72.3~228.0 1738~5468 2×560 79121
34 86.7~273.4 1962~6173 2×800 92227
36 102.9~324.7 2199~6921 2×1000 105763
RADW
  (A)
-12-NO
(n=490r/min)
24 25.3~79.9 674~2122 2×110 28738
25 28.6~90.3 732~2302 2×110 30936
26 32.2~101.6 791~2490 2×132 33894
27 36.1~113.8 853~2685 2×160 36701
28 40.2~126.9 918~2888 2×200 47169
29 44.7~140.9 985~3098 2×200 57271
30 49.5~156.0 1054~3315 2×250 63447
32 60.0~189.4 1199~3772 2×355 75121
34 72.0~227.1 1353~4258 2×450 88227
36 85.5~269.6 1517~4774 2×560 99763
38 100.5~317.1 1690~5319 2×800 134685
40 171.2~370.0 1873~5893 2×1000 150482
 
  Machine No. Volume
(m³/s)
Total Pressure
(Pa)
Power
(KW)
Weight
(kg)
RADW
  (B)
-6-NO
(n=980r/min)
15 14.5~36.6 805~2335 2×55 7456
16 17.6~44.4 916~2656 2×75 8730
17 21.1~53.3 1035~2999 2×90 9978
18 25.0~63.3 1160~3362 2×132 11120
19 29.4~74.4 1292~3746 2×160 16255
20 34.3~86.8 1432~4150 2×220 18635
21 39.7~100.5 1579~4576 2×280 22626
RADW
  (B)
-8-NO
(n=740r/min)
18 18.9~47.8 661~1917 2×55 10560
19 22.2~56.2 737~2136 2×75 15155
20 25.9~65.5 816~2367 2×90 16555
21 30.0~75.9 900~2609 2×132 19106
22 34.5~87.2 988~2863 2×160 21009
23 39.4~99.7 1080~3130 2×185 23184
24 44.8~I13.2 1176~3408 2×220 30538
25 50.6~128.0 1276~3698 2×280 34976
26 56.9~144.0 1380~3999 2×355 40234
27 63.7~161.0 1488~4313 2×355 42701
28 71.1~179.8 1600~4638 2×450 47569
RADW
  (B)
-10-NO
(n=590r/min)
21 23.9~60.5 572~1659 2×75 18026
22 27.5~69.5 628~1820 2×75 19569
23 31.4~79.5 686~1990 2×90 21584
24 35.7~90.3 747~2166 2×110 29118
25 40.3~102.1 811~2351 2×160 32236
26 45.4~114.8 877~2542 2×185 34634
27 50.8~128.6 946~2742 2×200 39501
28 56.7~143.4 1017~2949 2×250 42269
29 63.0~159.3 1091~3163 2×250 52371
30 69.7~176.4 1168~3385 2×315 62187
32 84.6~214.0 1329~385J 2×450 73121
34 101.5~256.7 1500~4348 2×560 85227
36 120.4~304.7 1682~4874 2×710 93763
RADW
  (B)
-12-NO
(n=490r/min)
25 33.5~84.8 559~1621 2×110 30936
26 37.7~95.3 605~1754 2×110 33134
27 42.2~106.8 652~1891 2×132 36361
28 47.1~119.1 702~2034 2×160 39169
29 52.3~132.3 753~2182 2×160 49271
30 57.9~146.5 806~2335 2×200 60447
32 70.3~177.7 916~2656 2×250 70121
34 84.3~213.2 1035~2999 2×315 80227
36 100.0~253.1 1160~3362 2×450 93763
38 117.6~297.6 1292~3746 2×560 120685
40 137.2~347.2 1432~4150 2×710 140482
42 158.8~401.9 1579~4576 2×1000 160781
44 182.6~462.1 1733~5022 2×1250 185583
Features

1. In order to meet the resistance requirements of coal mine ventilation network, and to ensure the efficiency of the fan, the machine uses a rotating structure, the two wheels are mutually reverse rotation, you can save the guide vane and reduce the loss of the guide vane, Improve the efficiency of the fan.
2. Adopt type of motor and impeller direct connection, to avoid damage to the transmission device, but also eliminates the energy loss of the transmission device to improve the efficiency of the fan device.
3. The motor is installed in the fan main fan in the closed cover, the enclosure has a certain pressure, can make the motor and fan flow channel containing gas gas isolation, but also play a certain role in the heat, Two rows of streamlined air duct, through the main air duct and the ground atmosphere, so that fresh air into the closed cover, while the air inside the fan in the fan running to maintain a positive pressure state.
4. The maximum hydrostatic efficiency of the fan up to 86% or more, wide efficient area, to ensure that the mine in the three stages of the main fan efficiency are more than 75%. Reversing the operation of China's large-scale mine main fan low efficiency, can save a lot of power.
5. Fan can reverse the wind, the amount of air up to 60% of the air volume, do not have another anti-air duct, with savings in infrastructure investment and the advantages of fast wind speed.
6. The impeller blade angle can be adjusted, according to the requirements of production to adjust the blade angle. The fan with a special design, performance curve without hump, in any case of network resistance, can be stable operation.
7. The series of fans running stable, small machine vibration, fan and diffuser can be installed in the wheeled flatbed, can be long-term continuous operation.
Sdf Tunnel Construction Axial Flow Fan Adjusted Tunnel Jet Fan
Ordering instructions
When ordering, please specify the fan number, speed, air volume, wind pressure, outlet angle and direction of rotation, as well as motor model, power, speed and so on.
The most important factors are volume and pressure.

 
Customized
When the exiting machine number, rotation, the wind angle and transmission mode can not meet the needs of users, we can design according to the fan similar theory and the user's specific parameters requirements.
Products Real Shot

Sdf Tunnel Construction Axial Flow Fan Adjusted Tunnel Jet FanSdf Tunnel Construction Axial Flow Fan Adjusted Tunnel Jet Fan


Technical Support Service
When using our products, If any problems on installation,operation,maintainance..and so on, please contact our sale manager directly or leave a message on our website, we will call you in the first time.
Application

Sdf Tunnel Construction Axial Flow Fan Adjusted Tunnel Jet Fan

Company Profile

KuangFeng brand mine fan have 6 series:XH-MF20/30,XH-CRMF25/35,XH-MLF66/68,XH-MLFD80,XH-RWD/RW/RADW. KuangFeng axial fan are built by Zibo Xinhua Fan Co.,Ltd. in Shandong, China. ZXF has served the mining and tunneling industries for 24 years.Since 1993.

We understand the harsh environments in which fans are used. KuangFeng fans will meet and exceed the demands of your mine or tunnel project.
 
KuangFeng has a wide selection of fans available,has been able to produce more than 200 series, more than 1200 kinds of products.

Contact to get a list of available fan sizes and to view detailed performance curves for each fan KuangFeng builds.

Sdf Tunnel Construction Axial Flow Fan Adjusted Tunnel Jet FanSdf Tunnel Construction Axial Flow Fan Adjusted Tunnel Jet Fan

Packaging & Shipping

Sdf Tunnel Construction Axial Flow Fan Adjusted Tunnel Jet Fan

FAQ

1.Q: What parameters need to be provided when you design the industrial centrifugal fans?
A: Air flow rate(m3/h), Total pressure(Pa) or Static pressure(Pa), Inlet temperature(°C), Voltage and frequency on the working site.

2. Q:What is your delivery time?
 A:15-35workdays, depending on the model of the fan.

3.Q:Are you manufacturer or trading company?
A:We are the professional manufacturer of centrifugal fans , over 30 years production experience and sales experience.

4.Q:What's your MOQ?
A:The MOQ is 1set,but larger quantity, lower price.

5.Q: What's your warranty?
A: 12 months after arrival of the goods on site.

6.Q:How do you control the product's quality?
A:All the products have quality testing and dynamic balance before delivery

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier